7130 W. 117th Ave.Suite D-3Broomfi eld, CO 80020Ph: 303-410-6639www.avocationsystems.comOperation ManualforHX SeriesHDMI Matrix UnitsRevision 2Oct 15,
C5Using Windows Hyperterminal with Ethernet ConnectionThe HX Series is controllable through any terminal software such as Hyperterminal. The followin
C6Using Putty with Ethernet ConnectionThe HX Series is controllable through any terminal software such as Putty. The following setup can be used to a
C7Changing the Units Baud RateThe MTX baud rate for communications is changed through the the front panel by using the following keystrokes.1) Press
D8Section D - CommandsThe Mountain Series has a number of commands for control and query to allow full control. Each command is listed in this sectio
D9Audio/Video/Digital Routing and Status MXxxBiioo ... A/D/V input to output MXxxBiio1,o2,o3,o4,o5
D10Legend:xx = unit ID number 00 to 15ii = input number 00 to 64oo = output number 01 to 64yy = value to setAudio Routing CommandsMXxxAiioo&l
D11MXxxAFoo<CR>Turn an audio output off MX00AF03<CR>Turn off audio output number 3Response: MXxx-Audio=00 to oo<CR>MXxxAMoo[y]<C
D12MXxxAUooyy<CR>Sets an audio output volume level MX00AU0132<CR>yy = 00 (-64dB Minimum)yy = 32 (0dB Pass Through)yy = 48 (+32dB Maximum)
D13MXxxSA[oo]<CR>Query for the status of an audio route. MX00SA<CR>Returns the status of all the audio routesMX00SA04<CR>Returns th
D14MXxxZ61ooyy<CR>Set the maximum volume level for an output MX00Z610432<CR>yy=00 to 48 Set the maximum volume for output 4 to 32Response
A2Read all instructions before connecting or operating the A/V Matrix. Pay particular attention to the safety information. Keep this manual so you
D15MXxxDFoo<CR>Turn a digital output off MX00DF03<CR>Turn off digital output number 3Response: MXxx-Digital=00 to oo<CR>MXxxSD(oo)&
D16MXxxVAii<CR>Routes a video input to all outputs MX00VA02<CR>Routes video input 2 to all video outputsResponse: MXxx-Video=ii to oo<
D17MXxxSB[oo]<CR>Read for the status of an a/v route. MX00SB<CR>Returns the status of all the a/v routesMX00SB04<CR>Returns the rou
D18MXxxZ13[y]<CR>Read Front Panel Control Status MX00Z13<CR>Response: MXxx-Front Panel is unlocked<CR>Disable Front Panel Control M
D19MXxxZ65[xxx.xxx.xxx.xxx]<CR>Read matrix IP Mask MX00Z65<CR>Response: MXxx-IP Netmask is 255.255.255.000<CR>Set matrix IP Address
D20MXxxZ70<CR>Reset matrix Ethernet confi guration to default MX00Z70<CR>Response: MXxx-IP Address is 192.168.000.075<CR> MXxx-IP
D21HDMI EDID CommandsHDMI Status/Debug CommandsMXxxH01<CR>Read HDMI Software Version MX00H01<CR>Response: MX00-Software Version: 017<C
D22MXxxH06Z<CR>Read HDMI Output Port Software Release Revision MX00H06Z<CR>Response: MX00-Output Port Processor - Software Release Rev: 0
E12314567890A/VFuncAudioPresetVideoCancelOffEnterWhen applying power to the matrix hold the “6” and “Audio” buttons. The front should say “boot”Sec
E2When the USB connection is in the matrix select “Connect”Plug the USB cable into the matrix now. 5678If you receive the following error the matri
A3Safety InstructionsThe lightning fl ash with arrowhead symbol, within an equilateral triangle, is intended to alert you to the presence of uninsulat
E3If successful press “Disconnect” and recycle the power on the matrix.9Select “Erase-Program-Verify” to program matrix10
7130 W. 117th Ave.Suite D-3Broomfi eld, CO 80020Ph: 303-410-6639www.avocationsystems.com
A411 Power-Cord Protection - Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or again
A5Be careful when unpacking the A/V Matrix. This electronic package is susceptible to dropping or holding heavy objects on top of it. Save the orig
C1Section C - Control ConnectionsThe HX series of matrices can be controlled via RS-232, USB, Ethernet and infrared.RS-232 Connections to the matrix
C2Using USBThe HX Series is controllable through the USB port of any PC. This connection is a standard serial port on the pc when connected. Accessin
C3Using Windows Hyperterminal with Serial ConnectionThe HX Series is controllable through any terminal software such as Hyperterminal. The following
C4Using Putty with Serial ConnectionThe HX Series is controllable through any terminal software such as Putty. The following setup can be used to all